This post was originally posted on FTTV by Benjamin Peterson. it's a huge help in trying to figure out what lighting area you may be in. This is a link to a video which explains the chart and how to read it made by me (Shane) - http://www.youtube.com/watch?v=hAT1e6bsOrY - From here forward is a direct copy and paste of his post.
This was posted on Monterfishkeepers.com by jcardona1.
Ok, so we all know the watts per gallon (wpg) rule is pretty much useless these days with all the different types of lighting. there are other ways using lumen calculation but i still dont like this, and is usually pretty damn confusing.
a member on plantedtank.net put together a great chart, using real data gathered with different bulbs and a PAR meter. this is awesome, and is a great reference for seeing what catergory of light youre in when it comes to plants. or how many bulbs you'll need to be in a certain category.
Size: 84.9 KB" border="0" title="Name: NEWPARVSDIST.jpg Views: 1757
Size: 84.9 KB" class="tcattdimgresizer" style="margin: 2px;" />
example, let's assume that i have a standard 55g tank(48x15x18). now, with a height of 18", let's say our light fixture will be 18" away from the bottom of the tank after taking into account your substrate depth of approx 2".
so based on this chart, if i were to run one T5HO bulb (assuming the bulb spans the length of the tank), this bulb would give me 65 micromols of PAR, which puts me in the MEDIUM light category. now if my fixture had two T5HO bulbs, just multiply the figure by 2, which gives us 130 micromols of PAR and well exceeds what is considered HIGH light. this may be too much lighting and could potentially give you algae problems. easy enought right???
same scenario, but let's assume we're using a standard T12 bulb. that gives us 10 micromols of PAR per bulb, which isnt even considered low light. we'd need 3-4 bulbs to be in the low light category. wanna be "high" light with T12 bulbs? gonna need at least 8 friggin bulbs!!!
now you see why T5HO are the most effecient and economical choice when it comes to lighting, especially for planted tanks.
so what do you guys think? can we put an end to all those wpg rules? i think this is easy enough, and should be a good guide for those wondering about lighting. afterall, the hardcore planted tank freaks ignored the wpg rule a long time ago!!!
here's the original quote, and full thread:
http://www.plantedtank.net/forums/li...t5-t12-pc.html
Tags:
got it! thanks dude.. its a power compact... i guess i just looked really quick ..lol
http://www.adana-usa.com/index.php?main_page=product_info&produ...
There is no real standard of measuring PAR so the only way to really find out what you have for your tank is to get a PAR meter and measure bottom, middle and top ot the tank. There is no mega high light though. Plants have a maximum amount of light that they will use. Say you put a metal halide over your tank and it gave you a PAR level that was at maximum for the plants you had. It wouldn't matter if you put 100 more halides over the tank, the plant could not use any more than its maximum PAR. Kind of like if you fill a glass with sand. Once its full, no matter how much more sand you pour onto the glass no more sand will get in.
Exactly right on the light levels. High PAR at the substrate is even higher at the surface. It's just that anything over a plants highest light requirement is wasted so you can't ever "overlight" a plant, but you will get algae. That's why you want to balance it out. You would use high light because some plants need that to thrive. It's just nature. Some plants need more sun than others.
When I say there is no standard I just mean that the chart is an estimate and the only true way to know is with a meter. You are absolutely right it's a good starting point, but every tank is different. The same light on two different tanks will give different readings because of tannins, shade of leaves, floating plants, etc. Even at the same depth, readings will vary between different areas of the same tank. That is why PAR readings are the most acurrate when done out of the water. But the chart is a good starting point. I would love to find a place that rents a PAR meter to see if the chart is right on. I'm sure some aquatic plant clubs rent them or loan them to members. There's a Boston Aquarium Society I think I'm gonna check out. Should be something like that in every city.
Personally I think a PAR meter for a planted tank is overkill and the chart is fine to use. I'd only get one if I had a reef tank with expensive coral. Then I'd want to know for sure.
To counteract the algae its good to plant more plants then right?
Does running the lights less time every day also reduce algae?
Short answer, no, it doesn't work that way.
is this also applicable to slim t5 bulbs or to t4 bulbs?
i have 2 10watt 5100k compact florescent ttwist in bulbs above about 10inches idk if this is even to be considered. i need help with reading this chart
Posted by Richard on December 29, 2019 at 10:59pm 0 Comments 0 Likes
Posted by Richard on December 29, 2019 at 10:58pm 0 Comments 0 Likes
Posted by Tuh Bahd Phish on March 5, 2019 at 10:12am 2 Comments 1 Like
Started by Richard in General Discussion (off topic). Last reply by Patrick Aug 16, 2020. 3 Replies 0 Likes
Started by Zachary Kittle in General Discussion (off topic) Oct 31, 2018. 0 Replies 0 Likes
Started by Zachary Kittle in General Discussion (off topic) Oct 30, 2018. 0 Replies 0 Likes
© 2024 Created by Dustin Wunderlich. Powered by